Roof Ventilation Calculator

Enter your attic size and the vents you prefer. You get the code minimum net free area, split into intake and exhaust, then converted into feet of ridge vent or a count of box vents.

Your attic

The ceiling area below the vented attic, not the roof surface.

1/300 only when the IRC R806.2 exception conditions are met (see below).

50 = balanced. Intake gets the rest.

Pre-filled with a typical rating. Use the number printed on your product.

Total length of ridge you could cut a vent slot into.

Check the package or spec sheet.

Total net free area
1,440sq in
Same thing in sq ft
10sq ft
Exhaust target
720sq in
Intake target
720sq in
Ridge vent needed
40linear ft
Continuous soffit vent strip needed
80linear ft
One exhaust type per attic. Don't mix ridge vents with box vents, turbines, gable louvers or a power fan over the same attic space. Round counts are already rounded up. Local codes can amend the ratios, so check with your building department.

How the ventilation math works

The calculation has two steps. First comes the code number: IRC section R806.2 (2021 text on UpCodes) requires net free vent area equal to 1/150 of the vented attic, measured at the floor (ceiling) level, not along the roof. Then you divide that area by the rating of each vent.

  • Total NFA (sq ft) = attic floor area / 150 (or / 300)
  • Total NFA (sq in) = sq ft x 144
  • Exhaust = total x exhaust share. Intake = total minus exhaust.
  • Vents needed = target sq in / NFA per vent, rounded up. For ridge vent or soffit strip, it's target / NFA per foot, which gives linear feet.
  • Power fans skip the ratio: CFM = attic sq ft x 0.7, and intake sq in = fan CFM / 300 x 144.

The worked example is what the tool shows when it loads. A 1,500 sq ft attic at 1/150 needs 1,500 / 150 = 10 sq ft of NFA, and times 144 that's 1,440 sq in. Split 50/50, that's 720 sq in up top and 720 down low. A ridge vent rated 18 sq in a foot needs 720 / 18 = 40 feet of ridge, and a continuous soffit strip at 9 sq in a foot needs 720 / 9 = 80 feet. The house has 50 feet of ridge, so ridge vent alone works.

Start at 1/150 unless you meet both 1/300 conditions

Use 1/150 unless both conditions in the current code are met. First, 40 to 50 percent of the vent area must sit in the upper attic, no more than 3 feet below the ridge (measured straight up and down), with the rest in the bottom third. Second, in climate zones 6, 7 and 8, there has to be a Class I or II vapor retarder on the warm-in-winter side of the ceiling.

You need both, not either. That's the 2021 wording, which is what most places enforce right now. Plenty of roofers use 1/150 no matter what, because it's cheap insurance.

Net free area by vent type

Net free area is the open hole left after you subtract the louvers, screens and baffles, and it is always smaller than the vent looks. These are the tool's defaults, and you can type over any of them with the number from your vent's box:

VentTypical NFAWhere the number comes from
Shingle-over ridge vent18 sq in per footAir Vent ShingleVent II, per its ICC-ES report (narrower 7 and 9 inch versions are 16)
Box vent / roof louver50 sq in eachLomanco 750 series (some box vents hit 60)
12-inch wind turbine95 sq in eachAir Vent, for most 12-inch turbines
12 x 18 in gable louver59.4 sq in eachAir Vent model 81214 listing
Continuous soffit strip9 sq in per footAir Vent model 84300
16 x 8 in undereave vent56 sq in eachAir Vent
Roof-edge intake vent9 sq in per footAir Vent's Edge Vent

The ridge figure is in ICC-ES report ESR-2071. The turbine, undereave and edge vent numbers come from an Air Vent University lesson plan that walks through this same shortcut (attic sq ft divided by 2 gives the sq in you need on each side, at 1/150). Lomanco's box vent number comes from the 750-G spec sheet.

Never mix exhaust types over one attic

This mistake shows up on a lot of houses. Someone adds a ridge vent and leaves the old box vents in place, assuming more is better. It isn't. Air takes the easiest path, so the ridge vent pulls air in through a box vent three feet away and ignores the soffits.

Air Vent's own help center is blunt about it: never mix two exhaust types over a common attic. The same goes for gable louvers and a power fan near a ridge vent.

Hip roofs often have too little ridge for a ridge vent

Hip roofs are the usual problem. They have four slopes and a short ridge, maybe 15 or 20 feet of it, while the math may call for 40. The tool warns you when the feet of ridge vent needed is more than the ridge you entered.

Your options are a higher-rated ridge vent or box vents across the whole attic instead. Ridge vent also usually stops a few inches short of each end, so a ridge that only barely fits is already tight.

Power fans are sized by CFM, not the ratio

Fans don't follow the ratio. Air Vent's rule of thumb is attic sq ft times 0.7 for the CFM, and its explanation says this works out to roughly 10 to 12 air changes an hour.

Intake is sized from the fan: CFM divided by 300 gives sq ft of intake (multiply by 144 for sq in), which keeps the incoming air slow enough that it won't drag dust in. With too little intake, a fan will pull conditioned air out of your house through the light fixtures.

Intake matters as much as exhaust

A ridge vent with painted-shut soffits does almost nothing. Exhaust is the part you can see from the street, so that's where the money tends to go. Check that insulation isn't packed into the eaves (baffles fix that).

Our soffit guide covers the panel types, and the roof ventilation guide has prices for each vent type. In snow country, a cold, well-vented deck is also a big part of ice dam prevention.

If you're replacing the roof anyway, that's the cheap time to fix ventilation, since the deck is open. The roof cost calculator prices the whole job, ridge vent included.

Roof ventilation questions

How many square inches of ventilation do I need per square foot of attic?

About one square inch for every square foot of attic floor at the 1/150 ratio. A 1,500 sq ft attic needs 1,440 sq in of vent, split half low and half high. At 1/300 you need half that.

Can I use 1/300 instead of 1/150?

Only if 40 to 50 percent of the vent area sits within 3 feet of the ridge and the rest is down low. In climate zones 6, 7 and 8 you also need a Class I or II vapor retarder on the warm side of the ceiling. Plenty of roofers stick with 1/150 anyway, since extra airflow rarely hurts.

Should intake and exhaust be equal?

Roughly, yes, and if you can't balance them, err toward more intake. An attic with more exhaust than intake starts pulling air out of the house through ceiling gaps, along with the heat and moisture you were trying to keep downstairs.

Can I keep my box vents and add a ridge vent?

No. Air Vent says never to mix two exhaust types over one attic. The ridge vent pulls air in through the nearest box vent instead of from the soffits, sometimes bringing rain and snow with it, and the lower attic barely moves. Pick one type and cap the rest.

How much ridge vent do I need for a 2,000 sq ft attic?

About 54 feet, at 1/150 with an 18 sq in per foot vent. The attic needs 1,920 sq in of vent in total, so 960 up high, and 960 divided by 18 is 53.3, rounded up. The other 960 sq in goes in the soffits, which is about 107 feet of a 9 sq in strip.

Pricing a whole roof?

The roof cost calculator turns your measurements into squares, materials and an installed price range.